High Accuracy Grade Of 0.01 Stationary Single-Phase Reference Standard Meter

Original
price: Negotiable
minimum:
Total supply:
Delivery term: The date of payment from buyers deliver within days
seat: Guangdong
Validity to: Long-term effective
Last update: 2017-12-28 03:23
Browse the number: 90
inquiry
Company Profile
 
 
Product details

 

High Accuracy Grade of 0.01 Stationary Single-Phase Reference Standard Meter

 

GENY’s reference standards adopt unique sampling technology, with high accuracy, wide testing range. They are suited for electric power utilities, energy meter manufactures, measuring and quality examining departments using as standards.

 

SZ-01A-K3E wide-range standard meter uses the newest electric technical in the world. The core of SZ-01A-K3E is high-speed DSPCPLD and MCU, it has the high-speed A/D converter with self-calibration at the same time. It can sample AC signal in high speed and deal with it in special way by DSP, this makes the circuit much simpler. It can calculate and measure AC signal exactly.


 

 

  • Feature and functions

     

  1. High accuracy up to 0.01%

  2. High stability

  3. Wide testing range

  4. Multiple function, measuring voltage, current, phase, frequency, power, energy etc.,

  5. Large size LCD display screen

  6. With communication port to PC

 

  • Specification

 

MODEL

SZ0A1-K3E

Standard conditions

Temperature of   environment: 20 ± 2  

Relative   humidity: 60 % ± 15 %

Supply power:   voltage 220V ± 22V

frequency 50Hz ± 2Hz

Magnetic   intensity: 0.025mT

Warm-up: the   time of warm-up 90minute

Rating current

0.001A0.01A0.1A1A (1A input port on the rear board)

10A  (10A input port on the rear board

100A (100A input   port on the rear board

Imax = 160A

Ratio voltage

50V100V200V400V  Umax = 480V

 

Precesion

current

± 0.01%RD  10mA120A      

± 0.03%RD  1mA10mA

 

Volage

± 0.01%RD  50V400V  

± 0.05%RD  5V50V

 

Power

 

Active power:

± 0.01%RD 50V400V0.05A120A , cosφ≥0.5

± 0.05%RD 50V400V0.001A0.05A , cosφ≥0.5 Reactive power:

± 0.01%RD  (50V400V0.05A120A , sinφ=1.0)

± 0.01%RD  (50V400V0.05A120A , sinφ=0.5L/0.8C)

 

energy

Active energy:

± 0.01%RD 50V400V0.05A120A , cosφ≥0.5

± 0.05%RD 50V400V0.001A0.05A , cosφ≥0.5 Reactive energy:

± 0.01%RD  (50V400V0.05A120A , sinφ=1.0)

± 0.05%RD  (50V400V0.05A120A , sinφ=0.5L/0.8C)

 

Power factor

Range of   measurement: 0~± 1.000000

Precision: ± 0.001%RDcosφ   0.5

 

phase

Range of   measurement: 0°~360°  

Precision: 0.003°  (U50V, I0.05A)

 

Frequency

Range of   measurement: 45Hz65Hz 

Precision: ± 0.0002%RD  (U50V)

 

Pulse Output

TTL level

load ability   > 2kΩ

Constant

CH=1012   imp/kW·h (imp/kvar·h) (00.001A ) 

CH=1011   imp/kW·h(imp/kvar·h) (0.0010.01A) 

CH=1010   imp/kW·h(imp/kvar·h) (0.010.1A) 

CH=109   imp/kW·h(imp/kvar·h) (0.11A) 

CH=108   imp/kW·h(imp/kvar·h) (110A) 

CH=107   imp/kW·h(imp/kvar·h) (10100A)

CL= CH / 50000   imp/kW·h(imp/kvar·h)

Use condition

Surrounding   temperature: 5 ℃~40  

Relative   humidity: 35%85%

 

Temperature affection

(5 ℃~40 )

Voltage, current   and frequency ±2ppm/  

Power   ±5ppm/

Communication port

RS-232

RS-485 (use for   manufacturer calibration)

 

Power supply

Voltage: AC220V   ± 22V

Frequency: 50Hz   ± 2Hz

Power   consumption: 45VA(max)

 

Dimension

W×H×D = 325mm×109mm×288mm

 

Weight

5.5kg

 

 

  • Primary Competitive Advantages

  1. High quality product

  2. High stability

  3. Friendly user interface

  4. Convenient operation 

  5. Long time warranty

     

     

  • Wiring

     

    1.  Wiring of 1A range

     

      


    2. Wiring of 10A range


 


    3. Wiring of 100A range

 

 

Total0bar [View All]  Related Comments
 
more»Other products